epigentek methylflash methylated dna quantification kit
Product Overview
The MethylFlash Methylated DNA Quantification Package (Fluorometric) is a whole set of optimized buffers and reagents to fluorometrically quantify international DNA methylation by particularly measuring ranges of 5-methylcytosine (5-mC) in a microplate-based format. In comparison with LUMA or LINE-1, Alu, and LTR-based assays, MethylFlash™ expertise straight quantifies precise international DNA methylation.
This equipment can also be particularly optimized for paired use with the MethylFlash Hydroxymethylated DNA Quantification Package (Fluorometric) for concurrently quantifying each methylated DNA and hydroxymethylated DNA.
Product Options
The MethylFlash™ Methylated DNA Quantification Package (Fluorometric) is an additional refinement of our earlier SuperSense™ international DNA methylation quantification kits by simplifying the workflow and enhancing the consistency of outcomes. It makes use of an progressive methodology to allow background alerts to be extraordinarily low, eliminating the plate drying and blocking steps. In comparison with chromatography-based strategies corresponding to HPLC or mass spectrometry, this product offers a cheap solution to precisely measure ranges of 5-methylcytosine. The equipment has the next benefits and options:
- Fluorometric assay with easy-to-follow steps for comfort and velocity. All the process might be completed inside four hours.
- Progressive equipment composition permits background alerts to be extraordinarily low, which eliminates the necessity for plate blocking and permits the assay to be easy, correct, dependable, and constant.
- Excessive sensitivity, of which the detection restrict might be as little as 50 pg of methylated DNA and accepts as little as 20 ng of enter genomic DNA
- Optimized antibody and enhancer options enable excessive specificity to 5-mC, with no cross-reactivity to unmethylated cytosine and no or negligible cross-reactivity to hydroxymethylcytosine throughout the indicated focus vary of the pattern DNA.
- Common optimistic and unfavourable controls are included, that are appropriate for quantifying methylated DNA from any species.
- Strip-well microplate format makes the assay versatile: guide or excessive throughput evaluation.
Precept & Process
The MethylFlash™ Methylated DNA Quantification Package (Fluorometric) comprises all reagents needed for the quantification of worldwide DNA methylation. On this assay, DNA is certain to strip wells which might be particularly handled to have a excessive DNA affinity. The methylated fraction of DNA is detected utilizing seize and detection antibodies after which quantified fluorometrically by studying the absorbance in a fluorescence microplate spectrophotometer at excitation 530 and emission 590 nm. The quantity of methylated DNA is proportional to the RFU (relative fluorescence models) measured, which might be calculated with the equipment’s included formulation for relative methylation standing of two totally different DNA samples or absolute quantification of 5-methylcytosine (5-mC) utilizing a typical curve.
Simple, Quick, and Versatile
All the fluorometric assay has easy-to-follow steps for comfort and velocity, which might be accomplished in four hours. The strip-well microplate format permits for a versatile assay in guide or excessive throughput evaluation. Common optimistic and unfavourable controls are included with the equipment for quantifying methylated DNA from any species corresponding to mammals, vegetation, fungi, micro organism, and viruses.
Secure and Handy
All of the wanted reagents, together with unfavourable controls and optimistic controls, for quantification of worldwide DNA methylation are conveniently packaged within the equipment. The direct fluorometric quantification of DNA samples replaces out of date or inferior strategies and eliminates the necessity for DNA digestion/denaturation, radioactivity, extraction, or chromatography.
Extremely Delicate and Particular
The novel process and proprietary equipment compositions enable for correct quantification of methylated DNA to be achieved with excessive sensitivity and specificity. The detection restrict of the enter DNA might be as little as 50 pg of methylated DNA.
MethylFlash (Fluorometric) | Competitor Z | Competitor C | |
---|---|---|---|
Assay Precept | Direct ELISA | Direct ELISA | Oblique ELISA |
Format | 96-well plate | 96-well plate | 96-well plate |
Sensitivity | Glorious detection restrict: 0.05 ng of 5-mC DNA | Good detection restrict: >0.5 ng of 5-mC DNA | Very poor detection restrict: >1000 ng of 5-mC DNA |
S/N Ratio | >20 with very low background | <four with excessive background | N/A* |
Procedural Comfort | No want for plate blocking and denaturation of DNA | Requires plate blocking and DNA denaturation | Requires plate blocking, DNA digestion, and antibody aggressive incubation in an extra plate |
Protocol Time | <four hr | <four hr | >eight hr |
DNA Kind & Species | Common for any species, each ssDNA and dsDNA | Human and mouse ssDNA solely | Numerous species |
Specificity | Particular to 5-mC solely | Cross-reaction to 5-hmC | N/A* |
Quantitation Kind | Each relative and absolute quantification | Relative | Relative |
Normal Management | Steady, quantitative in absolute quantity of 5-mC, and might be universally used for any species | Unstable, can’t be quantitative in quantity, and may solely be used for human or mouse | N/A* |
Minimal Enter Quantity | 20 ng | 100 ng | 1000 ng |
Accuracy of Detection | Excessive, steady and quantified customary management. Confirmed shut correlation with LC-MS evaluation by customers | Unclear, unstable and un-quantified customary management | N/A* |
% 5-mC calculation | Easy | Difficult | Not Offered |
Patented Technique | Sure | No | No |
Reputation | Very excessive printed quotation depend | Low printed quotation depend | Low printed quotation depend |
Help Experience | Since 2006 | Since 2013 | Since 2011 |
Product Options
The MethylFlash™ Methylated DNA Quantification Package (Colorimetric) is an additional refinement of our earlier Methylamp™ international DNA methylation quantification kits by simplifying the workflow and enhancing the consistency of outcomes. It makes use of an progressive methodology to allow background alerts to be extraordinarily low, eliminating the plate drying and blocking steps. In comparison with chromatography-based strategies corresponding to HPLC or mass spectrometry, this product offers a cheap solution to precisely measure ranges of 5-methylcytosine. The equipment has the next benefits and options:
- Colorimetric assay with easy-to-follow steps for comfort and velocity. All the process might be completed inside four hours.
- Progressive equipment composition permits background alerts to be extraordinarily low, which eliminates the necessity for plate blocking and permits the assay to be easy, correct, dependable, and constant.
- Excessive sensitivity, of which the detection restrict might be as little as 0.2 ng of methylated DNA and accepts as little as 50 ng of enter genomic DNA.
- Optimized antibody and enhancer options enable excessive specificity to 5mC, with no cross-reactivity to unmethylated cytosine and no or negligible cross-reactivity to hydroxymethylcytosine throughout the indicated focus vary of the pattern DNA.
- Common optimistic and unfavourable controls are included, that are appropriate for quantifying methylated DNA from any species.
- Strip-well microplate format makes the assay versatile: guide or excessive throughput evaluation.
Methylamp Universal Methylated DNA Kit | |||
P-1011 | EpiGentek |
|
|
Methylamp PCR Enhancer | |||
R-1002 | EpiGentek |
|
|
Methylamp 96 DNA Modification Kit | |||
P-1008 | EpiGentek |
|
|
Methylamp RNA Bisulfite Conversion Kit | |||
P-9003 | EpiGentek |
|
|
Methylamp Methylated DNA Capture (MeDIP) Kit | |||
P-1015 | EpiGentek |
|
|
Methylamp Universal Methylated DNA Preparation Kit | |||
P-1019 | EpiGentek | 40 µg | EUR 416.7 |
Methylamp One-Step DNA Modification Kit | |||
P-1010 | EpiGentek |
|
|
Methylamp Whole Cell Bisulfite Modification Kit | |||
P-1016 | EpiGentek |
|
|
Methylamp Coupled DNA Isolation & Modification Kit | |||
P-1002 | EpiGentek | 40 Samples | EUR 474.12 |
Methylamp Global DNA Methylation Quantification Ultra Kit | |||
P-1014B | EpiGentek |
|
|
Triplex ASFV Fast qPCR Kit | |||
E0472-01 | EURx | 24reactions | Ask for price |
Description: Certified for veterinary useFor African Swine Fever Virus detection, two internal controls, fast PCR |
Triplex ASFV Fast qPCR Kit | |||
E0472-02 | EURx | 96reactions | Ask for price |
Description: Certified for veterinary useFor African Swine Fever Virus detection, two internal controls, fast PCR |
Fast SG qPCR Master Mix (2x) | |||
E0411-01 | EURx | 100reactions | EUR 57.77 |
Description: For fast-cycling quantitative real-time PCR and two-step real-time RT-PCR |
Fast SG qPCR Master Mix (2x) | |||
E0411-02 | EURx | 200reactions | EUR 107.91 |
Description: For fast-cycling quantitative real-time PCR and two-step real-time RT-PCR |
Fast SG qPCR Master Mix (2x) | |||
E0411-03 | EURx | 1000reactions | EUR 510.12 |
Description: For fast-cycling quantitative real-time PCR and two-step real-time RT-PCR |
Fast Probe qPCR Master Mix (2x) | |||
E0422-01 | EURx | 100reactions | EUR 55.59 |
Description: For fast-cycling quantitative real-time PCR and two-step real-time RT-PCR Using sequence-specific probes |
Fast Probe qPCR Master Mix (2x) | |||
E0422-02 | EURx | 200reactions | EUR 106.82 |
Description: For fast-cycling quantitative real-time PCR and two-step real-time RT-PCR Using sequence-specific probes |
Fast Probe qPCR Master Mix (2x) | |||
E0422-03 | EURx | 1000reactions | EUR 467.61 |
Description: For fast-cycling quantitative real-time PCR and two-step real-time RT-PCR Using sequence-specific probes |
1ml Precision FAST qPCR Master Mix | |||
Z-PFAST-1ML | Novacyt Group | 1ml | EUR 90 |
Description: Precision®FAST |
2ml Precision FAST qPCR Master Mix | |||
Z-PFAST-2ML | Novacyt Group | 2ml | EUR 161 |
Description: Precision®FAST |
Fast SG/ROX qPCR Master Mix (2x) | |||
E0413-01 | EURx | 100reactions | EUR 61.04 |
Description: For fast-cycling quantitative real-time PCR and two-step real-time RT-PCR. Mix contains ROX dye |
Fast SG/ROX qPCR Master Mix (2x) | |||
E0413-02 | EURx | 200reactions | EUR 116.63 |
Description: For fast-cycling quantitative real-time PCR and two-step real-time RT-PCR. Mix contains ROX dye |
Fast SG/ROX qPCR Master Mix (2x) | |||
E0413-03 | EURx | 1000reactions | EUR 534.1 |
Description: For fast-cycling quantitative real-time PCR and two-step real-time RT-PCR. Mix contains ROX dye |
Genious 2X SYBR Green Fast qPCR Mix | |||
RK21204 | Abclonal | 1 mL | EUR 76.3 |
MethyLight qPCR Probe Kit | |||
RK21241 | Abclonal | 100RXN | EUR 209.83 |
2X Universal SYBR Green Fast qPCR Mix | |||
MBS9141672-25mL | MyBiosource | 25mL | EUR 755 |
2X Universal SYBR Green Fast qPCR Mix | |||
MBS9141672-5mL | MyBiosource | 5mL | EUR 255 |
2X Universal SYBR Green Fast qPCR Mix | |||
RK21203 | Abclonal | 1 mL | EUR 21.26 |
1ml Precision FAST CL qPCR Master Mix | |||
Z-PFAST-CL-1ML | Novacyt Group | 1ml | EUR 90 |
Description: Precision®FAST |
2ml Precision FAST CL qPCR Master Mix | |||
Z-PFAST-CL-2ML | Novacyt Group | 2ml | EUR 161 |
Description: Precision®FAST |
1ml Precision FAST LR qPCR Master Mix | |||
Z-PFAST-LR-1ML | Novacyt Group | 1ml | EUR 90 |
Description: Precision®FAST |
Fast EvaGreen® Master Mix for qPCR (5000 rxn) | |||
31003-2 | Biotium | 50x1ML | EUR 3452 |
Description: Recombinant Taq polymerase from E. coli |
Fast EvaGreen® Master Mix for qPCR (5000 rxn) | |||
31003-2-1 | Biotium | PK | EUR 3452 |
2X SYBR Green Fast qPCR Mix No Rox | |||
RK21200 | Abclonal | 50mL | EUR 109 |
Fast EvaGreen® Master Mix for qPCR(200 rxn) | |||
31003-1 | Biotium | 5x1ML | EUR 172 |
Description: Recombinant Taq polymerase from E. coli |
Fast EvaGreen® Master Mix for qPCR (500 rxn) | |||
31003-1-1 | Biotium | PK | EUR 379 |